Protection Circuit Module ( PCB ) for 7.4v Li-Ion / 6.4V LFP Battery Pack (2.5A Limit) -For 18650/18500-2S1P battery pack (50 pcs Min) (#6244)
|
Call for Order & Lead Time
Product Options
Voltage: |
|
|
This protection circuit is specially designed for 7.4V Li-Ion / 6.4V LiFePO4 Battery pack with 2.5A discharging rate.
Protection Circuit Module Specifications |
Model:PCM-SM33 series |
|
For Li-ion |
For LiFePO4 |
Charging Voltage (CC/CV) |
4.2V/Cell |
3.60V/Cell |
Over charge detection voltage |
4.25±0.025V |
3.8±0.025V |
Over discharge detection voltage |
2.40±0.062V |
|
Over current detection current |
5±1A |
Maximal continuous discharging current |
2.5A |
Current consumption for single cell |
≤20uA |
Protection circuitry resistance (B- TO P-) |
≤60mΩ |
Dimension |
33mm x 14.7 mm |
P+/P- |
P+ = Charge+ / Discharge + P- = Charge- / Discharge -
|
Specification |
PCB For 7.4V Li-ion
|
For other PCM/PCB, please check our PCM/PCB/BMS/CMB/UPS category Warning
- If you want to use this protection circuit board for a battery that is less than the rated drain, you must add additional protection device to protect the battery itself. Such as: proper rated polyswitch.
- To achieve balance, each cell in battery pack must has equal voltage within tolerance. When charger LED turn Green, allow 30 minutes for pack to balance before use.
- You must be professional in Lithium battery pack to buy the protection circuit board. Misusing may cause battery damage or explode. We are not responsible for any damage caused by user.
|