Powercom Line Interactive UPS (Model type: BLACK KNIGHT PRO, Model name: BNT-1500AP)

Your Price: $158.99
In Stock

Product ID # 4194
Part Number:

Line interactive products providing the great Power Backup solution from desktop to datacenter, and given you the perfect interactive experence . This fully digitized microprocessor controlled line interactive UPS support auto voltage regulation, cold starting, lightning and surge protection, tel/modem internet surge suppression and use software to schedule shutdown, record power failure history and show basic parameters such as input/output voltage, input/output frequency, battery level, load level.


  • Model type: BLACK KNIGHT PRO, Model name:BNT-1500AP
  • AC Input
    • AC Input Capacity on Battery: 1500VA
    • AC Input Voltage:100V or 110V/115V/120V or 220V/230V/240V +/- 25% at line input
    • AC Input Frequency: 50 or 60 Hz+/-5% (auto sensing
  • AC Output
    • AC Output Voltage: Simulated sine wave at 100V or 110V/115V/120V or 220V/230V/240V +/- 25% 
    • AC Output Frequency: 50 or 60 Hz +/- 0.5%
    • AC Output Voltage Regulation: AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal. AVR decrease output voltage 13% below input voltage if +9% to +25% of norminal
    • AC Output Transfer: 2/4 milliseconds, including detection time
    • Protection Spike: 480 Joules / 2ms
    • Protection Overload: UPS automatic shutdown if overload exceeds 110% nominal at 60 sec and 130% at 3 sec
    • Protection Unit: Fuse for overload & short circuit protection
    • Protection Inside Protection: UPS output cut off immediately or input fuse protection 
    • Battery Type: SLA 
    • Battery Typical: Recharge 6 hours (to 90% of full capacity)
    • Battery Protection: Auto discharge protection
    • Battery Burn-time: 70- 80 minutes
    • 13.4 Kg (29.5lb)
    • Physical Dimension (LxWxH):382(15.0")x130(5.1")x192(7.6")
    • Alarm Battery Backup:  Slow beeping sound (about 0.47 Hz)
    • Alarm Battery Low:Rapid beeping sound (about 1.82 Hz)
    • Alarm Overload:  Continue beeping sound
    •  Interface RS-232: Yes
    •  Environment Ambient:3,500 meters max. elevation, 0-95% humidity non-condensing, 0-40 deg C (32'F-104'F)
    • Environment Audible: <40dBA (1 meter from surface)
    • Environment Storage Condition: 15,000 meters max. elevation

Related Products

Product Reviews

(0 Ratings, 0 Reviews)

Thermal Spread Material used in Battery Pack Assembly
UN 38.3 Safety Test

We own a national standard UN38.3 testing lab. We can provide UN38.3 test service to our customer.

If you want to set up your own lab, we also provide UN38.3 & IEC62133 equipments and onsite training. Email us for the quote and lead time.
Thermal Abuse Test for IEC62133
Lithium Battery Shipping Regulation
Show & Conference
Lithium Battery Power and Safety, Baltimore MD, Nov 17-19, 2015
The Battery Show, Novi. MI, Sept 15-17, 2015 Booth#1716
Battery Power 2015, Denver, CO, August 5-6, 2015 Booth#29
Next Generation Batteries Conference, San Diego, CA, April 21-22, Booth#9
32nd International Battery Exhibit, Mar.9-12,2015, Florida, Booth #209
More ...
Mailing Lists